ACL - Apollo Computing Laboratories (P) Ltd.,established in 1992 at Hyderabad has been involved in the Manufacturing of Electronic Systems in the domain of embedded computing for the National Programmes of Defence & Aerospace organisations. Parallelly, ACL has established Environmental Test Facility at their Factory premises to cater to the needs of Qualification & Acceptance testing according to various Defence Standards. Apart from catering to our own testing requirements, these facilities are available for other organisations also at reasonable charges.
We can conduct
Dynamic Tests : Vibration ,Acceleration, Shock & Bump
Climatic Tests : Temperature Cycling, High Temperature, Low Temperature, Damp ,Heat Tropical Exposure, Burn-in
Capacity 2500 Kgf
-
Capacity :2500 kgf
-
Max Acceleration ( Bare Table ) :75g is sine mode and 53g in Random mode
-
Frequency Range :Up to 2.2 KHz
-
Shaker Rotaion :±90o to connect to the Slip table
Capacity 5000 Kgf
-
Acceleration Range :1 to 100 G
-
Capacity :5000 G-KgMaximum
-
Payload :50 Kg
-
Payload size :550 x 550 x 550 mmSpeed Range :30 to 400 R.P.M
Table Size : 750 x 750 mm
-
Table Size : 750 x 750 mm
-
Table Weight :100 KgMax
-
Specimen Weight :150 Kg ( Including Fixture weight )
-
Max Specimen size(mm) :750(W) X 750(T) X Unlimited(H)
-
Minimum Pulse Width :6 ± 1 milli seconds
-
Maximum Pulse Width :15 milli seconds ( ± 10%)
-
Maximum Acceleration :Up to 15 to 50 'g' ( ± 10%)
-
Cycling Rate :60 to 180 bumps per minute
Thermal cycling chamber type - I Specifications:
-
Type : Temperature & Humidity Chamber
-
Temperature Range : - 65 °C to +110°C
-
Humidity Range : 20 to 95% RH
-
Rate of Heating/Cooling :5 °C /minute
-
Workspace Dimensions :1 mtr (W) X 1mtr (ID) X l mtr (H)
Thermal cycling chamber type - II Specifications:
-
Type of Chamber : Temperature
Humidity
-
Temperature Range : -70 °C to +180 °
C
-
Humidity Range : 10 to 98% RH
-
Rate of Heating /
Cooling :
10 °C/minute
-
Workspace Dimensions :61Omm(W) X 610mm(D) X 610mm(H)
Thermal cycling chamber type - III Specifications:
-
Type of Chamber : Temperature
- HumidityTemperature Range : -70 °C to +180 °C
-
Humidity Range : 10 to 95% RH
-
Rate of Heating / Cooling
:
2 °C/minute
-
Workspace Dimensions : 450mm(W) X 450mm(D) X 450mm(H)
Hot air chamber Specifications:
-
Type of Chamber : Temperature
-
Temperature Range : +130 °C
-
Workspace
Dimensions
:300mm(W) X 300mm(D) X 300mm(H)
Partner With us
- Facilities are available for other organisations also at reasonable charges.
- Our Organisation is approved by CEMILAC as Design Agency for Airborne Equipments / LRUs (On Board Systems and Ground Systems)Our Organisation is AS 9100D and ISO 9001:2015
- certified by NVT QC
ACL Objectives
- To design products that take advantage of latest state-of-the-art technologies.
- To provide high quality, high-performance & innovative products (both Hardware and Software).
- To provide incrementally expandable, scalable, modular, and upgradable computing solutions.
- To provide cost-effective solutions for turnkey projects using open systems.
- To under take quantity production.
- To provide training in the emerging technologies.
- To play a role in the indigenisation programs of Defence & Aerospace.